T1: Indexing axes
15.5 Equidistant index intervals
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
785
Delete distance-to-go
After traversing to the next possible indexing position, the movement is aborted at this
position.
Command axes
If MOV=0 is specified for a moving command axis, the axis continues traversing to the next
possible indexing position.
References:
Function Manual, Synchronized Actions
MOV command
MOV=1
Works on indexing axes with and without Hirth tooth system.
MOV=0
Same function for both: Approaches the next position.
DELDTG command
In the case of indexing axes without Hirth tooth
system:
Axis stops immediately.
In the case of indexing axes with Hirth tooth
system:
Axis traverses to next position.
15.5.4 Restrictions
Transformations
The axis for which the Hirth tooth system is defined cannot take part in kinematic
transformations.
PRESET
The axis for which the Hirth tooth system is defined cannot be set to a new value with
PRESET.
Revolutional feedrate
The axis for which the Hirth tooth system is defined cannot be traversed at revolutional
feedrate.