S7: Memory configuration
14.2 Memory organization
Extended Functions
756 Function Manual, 03/2013, 6FC5397-1BP40-3BA1
14.2 Memory organization
14.2.1 Active and passive file system
The static NC memory contains an active and passive file system.
Active file system
The active file system contains system data used to parameterize the NCK:
Machine data
Setting data
Option data
Global user data (GUD)
Tool-offset/magazine data
Protection zones
R parameters
Work offsets/FRAME
Sag compensations
Quadrant error compensation
Leadscrew error compensation
This data represents the current work data of the NCK.
The user's view of the active file system is data-oriented.
Passive file system
The passive file system contains all files loaded onto the NCK:
Main programs
Subprograms
Global-user-data and macro definition files (*.DEF)
Standard cycles
User cycles
Workpieces
Comments
The user's view of the passive file system is file-oriented.