Z2: NC/PLC interface signals
18.10 Positioning axes (P2)
Extended Functions
894 Function Manual, 03/2013, 6FC5397-1BP40-3BA1
18.10 Positioning axes (P2)
The following signals or commands on the NCK-HMI-PLC interface are only of significance
for the positioning axis:
3RVLWLRQLQJD[LV
)&&RQFXUUHQWSRVLWLRQLQJD[HV
,6'HOHWHGLVWDQFHWRJRD[LVVSHFLILF
,6)HHGUDWHVSLQGOHRYHUULGHD[LVVSHFLILF
,6)IXQFWLRQIRUSRVLWLRQLQJD[LVLIVHWIURP73
,63RVLWLRQLQJD[LV
Figure 18-2 Signal modification by the PLC
18.10.1 Signals to axis/spindle (DB31, ...)
DB31, ...
DBB0
Feedrate override / spindle override axis-specific
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 or edge
change 0 → 1
Positioning axes have their own axis-specific feedrate override value. This feedrate override
is evaluated in the same way as the channel-specific feedrate override.
Signal irrelevant for ... NST DB31, ... DBX74.5 ("Positioning axis") = ZERO
References Evaluation see:
DB21, ... DBB4 (feedrate override); channel-specific
DB31, ...
DBX2.2
Delete distance-to-go, axis-specific
Edge evaluation: Yes Signal(s) updated: Cyclic
Signal state 1 or edge
change 0 → 1
The axis-specific distance-to-go of the positioning axis is canceled. The positioning axis is
decelerated and the following error is eliminated. The programmed end position is deemed to
have been reached. The path axes are not influenced by the axis-specific "delete distance-to-
go" interface signal. The channel-specific "delete distance-to-go" interface signal is used for
this purpose.
Special cases,
errors, ...
If the axis-specific "delete distance-to-go" interface signal is enabled, even if no positioning
axes have been programmed in this block, the NCK does not respond.
Corresponding to ... DB21, ... DBX6.2 (delete distance-to-go); channel-specific for path axes