182
406273/C
SettingupdataexporttoOlex
TheES80allowsyoutoexportdatatotheproprietaryOlexsystem.Theoutput
parametersforthedataexportaredenedintheOutputdialogbox.
Prerequisites
Thisprocedureassumesthat:
•TheEthernetadapterintheProcessorUnitissetupwithauniqueIPaddress.
•TheOlexcomputerisconnectedtotheProcessorUnit.
Procedure
1SelectOperation,andsetittoInactive.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.Thisdialogboxcontainsanumber
ofpagesselectedfromthemenuontheleftside.
3OntheleftsideoftheInstallationdialogbox,selectI/OSetup.
4SetuptheEthernet(LAN)portcommunicationparameters.
aSelectAddLANPort.
bOntheI/OSetuppage,selecttheportyouwishtosetup.
cSelectSetupbelowthelisttoopentheLANPortSetupdialogbox.
dSetuptherelevantcommunicationparameters.
•Name:Olex
•LocalIPAddress:157.237.1420
•LocalPort:2020
•RemoteIPAddress:157.237.14.13
•RemotePort:2020
eSelectApply.
fSelectOKtosavetheselectedsettingsandclosethedialogbox.
5SelectOperation,andsetittoNormal.
6OpentheSetupmenu.
7SelectOutput.
ObservethattheOutputdialogboxopens.Thisdialogboxcontainsanumberof
pagesselectedbythemenuontheleftside.
SimradES80ReferenceManual