Loading...
182
406273/C
SettingupdataexporttoOlex
TheES80allowsyoutoexportdatatotheproprietaryOlexsystem.Theoutput
parametersforthedataexportaredenedintheOutputdialogbox.
Prerequisites
Thisprocedureassumesthat:
TheEthernetadapterintheProcessorUnitissetupwithauniqueIPaddress.
TheOlexcomputerisconnectedtotheProcessorUnit.
Procedure
1SelectOperation,andsetittoInactive.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.Thisdialogboxcontainsanumber
ofpagesselectedfromthemenuontheleftside.
3OntheleftsideoftheInstallationdialogbox,selectI/OSetup.
4SetuptheEthernet(LAN)portcommunicationparameters.
aSelectAddLANPort.
bOntheI/OSetuppage,selecttheportyouwishtosetup.
cSelectSetupbelowthelisttoopentheLANPortSetupdialogbox.
dSetuptherelevantcommunicationparameters.
Name:Olex
LocalIPAddress:157.237.1420
LocalPort:2020
RemoteIPAddress:157.237.14.13
RemotePort:2020
eSelectApply.
fSelectOKtosavetheselectedsettingsandclosethedialogbox.
5SelectOperation,andsetittoNormal.
6OpentheSetupmenu.
7SelectOutput.
ObservethattheOutputdialogboxopens.Thisdialogboxcontainsanumberof
pagesselectedbythemenuontheleftside.