490
406273/C
Note
InsomeproprietarytelegramsreceivedfromotherKongsbergMaritimeequipment,the
$characterisreplacedbythe@character.Thechecksumeldmaythennotbeinuse.
StandardNMEA0183communicationparameters
TheES80usesbothNMEAandproprietarydatagramformatstocommunicatewith
peripheralsystemsandsensors.ThemajorityofthedatagramsusedbytheES80are
denedbytheNationalMarineElectronicsAssociation(NMEA).NMEAhasdeneda
xedsetoftransmissionparameters.
ThecommunicationparametersdenedforNMEA0183are:
BaudRate:4800b/s
DataBits:8
Parity:None
StopBits:1
Someinstrumentsmayofferotherparametersand/oroptions.Youmustalwayscheck
therelevantdocumentationprovidedbythemanufacturer.