NMEADPTdatagram
TheNMEADPTdatagramprovidesthewaterdepthrelativetothetransducer,andthe
offsetofthemeasuringtransducer.
Format
$--DPT,x.x,y.y,z.z*hh<CR><LF>
Description
Thisdescriptionisnotcomplete.Foradditionaldetails,refertotheNMEAstandard.
1$—:Talkeridentier
2DPT:Datagramidentier
3x.x:Depth(Metres),Relativetothetransducer
4y.y:Offset(Metres),Relativetothetransducer
Positiveoffsetnumbersprovidethedistancefromthetransducertothewater
line.Negativeoffsetnumbersprovidethedistancefromthetransducertothepart
ofthekeelofinterest.
5z.z:Maximumrangescaleinuse
6*hh:Checksum
Tip
Ifyouneedthedepthbelowthekeel,usetheNMEADBKdatagram.Ifyouneedthe
depthbelowthesurface,usetheNMEADBSdatagram.Ifyouneedthedepthbelowthe
transducer,usetheNMEADBTdatagram.