Onceatransducerhasbeeninstalled,itislistedintheInstalledTransducersbox.Tosee
theinformationyouhavecollectedaboutthetransducer,selecttherelevanttransducer
inthelist.
TheEditfunctionalityontheTransducerInstallationpagemakesitpossibletochange
theinformationyouhaveprovidedforthetransducer.Y oucannotchangethemodel
identicationandtheserialnumber.Thecustomnameisusedseveralplacesintheuser
interface,anditcanbechanged.
TheRemovefunctionalityontheTransducerInstallationpagemakesitpossibletodelete
theinformationyouhaveprovidedforthetransducer.Thereisno"undo"functionality.
Installingtransceiverchannels
InordertousetheES80,theProcessorUnitmustbeconnectedtooneormore
transceivers,andeachofthemmustinturnbeconnectedtooneormoretransducers.
Eachchannelmustbeinstalledbeforeitcanbeputtouse.Inthiscontext,thephrase
channelisusedasacommontermtoidentifythecombinationoftransceiver,transducer
andoperatingfrequency.
Prerequisites
TheES80isinstalledasspeciedintheES80Installationmanual.
•Allcablesareconnectedandtested.
•Eachtransceiverispoweredup.
•Thesoftwarelicenseforeachtransceiverisinstalledandactivated.
•TheEthernetadapterintheProcessorUnitissetupwithauniqueIPaddress.
•AllrelevanttransducersareinstalledusingtheTransducerpage.
Context
TheTransceiverInstallationparameterscontroltheinstallationanddisconnectionof
transceivers.Everytimethepageisopened,theES80softwareautomaticallyperformsa
searchontheEthernetnetworkfortransceivers.
ThelistintheupperpartontheTransceiverInstallationpageshowsyouanoverview
ofthetransceiversandchannelsthatarecurrentlyavailable.Inthiscontext,thephrase
channelisusedasacommontermtoidentifythecombinationoftransceiver,transducer
andoperatingfrequency.Eachchannelisidentiedbythetransceivertypeandserial
numberandthetransducer(s)inuse.Thecurrentstatusforeachchannelisalsoprovided.
•Busy:Thechannelisalreadyinuse,probablybyanotherechosounderonthesame
network.Y oucannotconnecttothischannel.
•Installed:ThischannelisconnectedtoyourES80system.
•Lost:Thischannelcannotbeused.