406273/C
375
ThecommunicationparametersdenedforNMEA0183are:
•BaudRate:4800b/s
•DataBits:8
•Parity:None
•StopBits:1
Someinstrumentsmayofferotherparametersand/oroptions.Youmustalways
checktherelevantdocumentationprovidedbythemanufacturer.
Monitor
IfyoususpectthataserialportorLANportisineffective,faultyormissing,you
canmonitortheowofdatagrams.SelectoneofthelistedportsandthenMonitor
toobservethedatacommunication.ThePortMonitordialogboxopens.
Returnto...
Installationdialogbox,page346
Outputdialogbox,page386
Relatedtasks
Installingnavigationsensorsandothersensors,page164
DeningtheserialandEthernet(LAN)portparameters,page165
Relateddialogboxes
BITE(Built-InTestEquipment)dialogbox,page400
BITE:Sensorspage,page404
LANPortSetupdialogbox,page442
SerialPortSetupdialogbox,page444
PortMonitordialogbox,page446
AddSerialPortdialogbox,page448
Synchronizationpage
ThepurposeoftheSynchronizationparametersistosetuptheES80tooperatealone,
orasamasterorslaveinasynchronizedsystem.Synchronizationisrequiredinorder
toavoidinterferenceiftheES80isusedsimultaneouslywithotherhydroacoustic
instrumentswithinthesamefrequencyrange.
Prerequisites
TheInstallationdialogboxisnotavailablewhenyourES80issettoReplaymode.
Functionsanddialogboxes