406273/C
185
7SelectSynchronizationDelay.
Thisdelayparameterisuseddifferentlydependingonthechosensynchronization
mode.
Stand-alone
TheSynchronizationDelaysettingisnotapplicablewhensynchronizationis
switchedoff.
Master
InMastermode,theES80waitsforthedelaytimeaftertheexternaltrigger
signalhasbeensenttotheslavesbeforetransmittingtheping.Thisisoften
referredtoasapre-trigger.
Note
Thisdelaywillonlyworkwhenthesynchronizationissetupusingaserialport.
Slave
InSlavemode,theES80waitsforthedelaytimeaftertheexternaltriggersignal
hasarrivedbeforetransmittingtheping.Thisisoftenreferredtoasapost-trigger.
8Fromthelistofportsavailable,selectSynchronizationPort.
Thisistheinterfaceportcurrentlyusedtotransmitorreceivesynchronization
signals.ItmustbeanRS-232serialport.Sincethesynchronizationfunctiononly
usestheRequestToSend(RTS)andClearToSend(CTS)signalsonaserialport,
youcanuseaportthatisalreadyusedforotherpurposes.Forthesamereason,
youdonotneedtodeneanybaudrate.
9Atthebottomofthepage,selectApplytosaveyoursettings.
10ContinueyourworkintheInstallationdialogbox,orselectOKtocloseit.
SynchronizingtheES80bymeansofaserialport
IfyouwanttousetheES80asamasterorslaveinasynchronizedsystem,youmustset
itupforsuchoperation.Todothis,youmustselectwhichcommunicationporttousefor
thesynchronizationinterface,andyoumustselecttherequestedsynchronizationmode.
Prerequisites
Thisprocedureassumesthat:
Thevesselisberthedoratsea.
YouhaveanRS2-232interfaceportonyourProcessorUnitthatallowsyoutousethe
CTS/RTSconnections.
For"slave"operation,aremotesystem(forexampleK-Sync)mustbeavailableto
providetriggerpulses.For"master"operation,aremotehydroacousticsystem(sonar,
echosounder)isconnected.Thisremotesystemmustbesetupin"slave"mode.
Operatingprocedures