406273/C
259
FThisisthelowerendofthechosendepthrange
Thisdepthisnormallyafewmetersbelowthebottomcontour,dependingonthe
chosenrange.Thetotalechogramrange(A)to(F)isdenedwiththeRangebutton
ontheMainmenu.
Example
StartRange
inasurfacerelatedechogram
Inasurfaceechogram,settheStartRangevalueto10meters.Thiswillmake
theechogramstartfrom10metersbelowtheseasurface(providedthatthe
transduceroffsethasbeendened).SetRangetothecurrentdepthplus20
meters.Theechogramwillnowshowtheareafrom10metersbelowthesea
surface,anddownto10meters“below”thebottom.Thebottomcontouris
easilydetectedwhenthedepthchanges.