406273/C
509
T:Temperature
C:Catch
B:Bottom
N:Nosensor
M:Marker
7U:Unit
M(meters),f(feet)orF(fathoms)fordepthmeasurements
C(Celsius)orF(Fahrenheit)fortemperaturemeasurements
8S:Source
Thenumber(1,2or3)ofthesensorprovidingthecurrentdatavalues
9C:Channel
Thenumber(1to30)ofthecommunicationchannelforthecurrentdatasource
10V:Value
Themagnitudeofthecurrentsensormeasurement
11Cr:Changerate
Themagnitudeofthecurrentdepthortemperaturemeasurement
12Q:Quality
0:Noconnectionbetweenthesensorandthereceiver
1:Oneortwotelemetrypulsesarelost,currentvalueispredicted
2:Thecurrentdatavalueisreliable
13In:Interference
0:Nointerference
1:Interferenceisdetected
14SL:Signallevel
Thesignallevelofthetelemetrypulse,measuredindB//1µPa
15NL:Noiselevel
Theaveragenoiselevelofthecurrentchannel,measuredindB//1µPa
16G:currentgain,0,20or40dB
17Cb:Cablequality
0:Cableisnotconnected
1:CableisOK
2:Ashortcircuit,orthehydrophonecurrentistoolarge
18error:Errordetected
0whennoerrorisdetected,anumber>0indicatesanerrorcondition