60
406273/C
aTurnontheProcessorUnit.
bMakesurethatyouhaveadministrativerights.
cSwitchoffanyrewallapplications.
dOpentheoperatingsystems’sNetworkandSharingCenter,andsettheIP
addressforthenetworkadapterusedtocommunicatewiththetransceiver.
•IPAddress:157.237.15.12(Recommended)
•Subnetmask:255.255.255.0
2InstalltheES80operationalsoftware.
3Turnonthetransceiver(s).
4MakesurethattheProcessorUnitisconnectedtothetransceiver(s)usingthe
EthernetcablespeciedintheES80Installationmanual.
Ifyouusemorethanonetransceiver,ahighperformanceEthernetswitchmust
beused.
Note
Itisveryimportantthatahigh-qualityEthernetcableisused.Youmustuse
CAT-5ESTP(ShieldedTwistedPair)qualityorbetter .Ifyouusecableswithlower
bandwidthcapacityyouwillreducetheES80performance.
5StarttheES80.
6OntheSoftwareLicensepage,installthesoftwarelicense(s).
7OntheTransducerpage,installeachtransducer.
8OntheTransceiverInstallationpage,connectthetransducer(s)tothetransceiver(s).
9OntheSensorInstallationpage,setuptheinterfacestothenavigationsensors.
10Startnormaloperation.
aSetOperationtoNormal.
bIntheNormalOperationdialogbox,settheoperationalparameters.
cSetPingModetoMaximum.
dSetPingtoOn.
SimradES80ReferenceManual