EasyManuals Logo

Symmetricom TimeProvider 5000 User Manual

Symmetricom TimeProvider 5000
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
116 TimeProvider 5000 User’s Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
The IOC module IP address is part of the configuration file. When restoring the
IOC module configuration file to a different TimeProvider 5000, the user must set
the IOC module IP address to avoid conflict with TimeProvider 5000 units that
had the configuration file before being exported for backup. See the set ip
command.
When restoring configuration files to a different TimeProvider 5000, the PTP
Clock ID must be reinitialized back to its default setting. To re-initialize the PTP
Clock ID use the following command:
tp5000> set ptp clockid ioc1-[x] ff:ff:ff:ff:ff:ff:ff:ff
<enter>
Use SFTP when exporting or importing the IMC module and IOC module
configuration files. SFTP is the same mechanism used for TimeProvider 5000
firmware downloads.
For remote storage, path names should be specified as appropriate for the
FTP/SFTP server and the operating system it is running on. This includes
whether the entire path should be specified and whether "/" or "\" characters
should be used.
Level : Admin only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals