Row Crop Seed setup 6 Field-IQ crop input control setup
Setting Explanation
Seeds Per Pound Number of seeds per pound.
Target Rate Units If you select this option, choose one of these at the Target
Rate Units screen: Default (kS/a or kS/ha), Bushels.
Bushel Weight Weight per bushel
5. At the Application Rate Setup screen, tap Row Monitoring.
6. At the Row Monitoring Setup screen, enter the correct settings. When you are finished, tap
.
a.
Alarms
Alarm Setting Explanation
High Alarm Triggers when the seed sensor population rises above the
selected percentage from the Target Rate for longer than the
delay time.
Low Alarm Triggers when the seed sensor population drops below the
selected percentage from the Target Rate for longer than the
delay time.
Singulation Low Triggers when the singulation drops below the selected
percentage lower than 100% for longer than the delay time.
Seeds When Off Triggers when this percentage of seeds are detected while
the sections are off for longer than the delay time.
No Seeds When On Triggers when this percentage of seeds are not detected for
longer than the delay time.
Blockage Sensitivity Triggers when less than this amount of material is sensed for
longer than the delay time.
b.
Delays
Delay Settings Explanation
High Alarm Amount of time that the row sensor population has to be
above the High Alarm setting before warning.
Version 7.0, Revision A CFX-750 Display User Guide 125