PERIPHERALS
ENTRIES FOR A PERIPHERAL
200 ENVOY™ TRANSCEIVER REFERENCE MANUAL
RFU Sidetone Volume
The RFU Sidetone Volume entry sets the volume of the call and ring tones heard
at the 15-way port.
Range: –16 to 16
Default value: 0
RFU Secure Audio
The RFU Secure Audio entry sets whether or not secure audio is present on the
15-way port.
Default value: Disabled
RFU Quiet Line
The RFU Quiet Line entry sets the behaviour of the Quiet line input to pause
scanning in the transceiver. This can be set to detect either a high-going or low-going
signal from your modem.
NOTE: Please refer to the documentation provided with your modem to
determine which type of signal it outputs to the Quiet line.
If your modem:
• outputs a low signal to the Quiet line, select Pause scan when low
• outputs a high signal to the Quiet line, select Pause scan when high
• does not have a detect output, select Disabled
NOTE: When the transceiver is used with a modem that does not have a
detect output, the transceiver must have scanning switched off,
and data communications must take place on an agreed channel.
Default value: Disabled
RFU 15way MIL/STANAG 2G Data Interface
The RFU 15way MIL/STANAG 2G Data Interface entry sets whether or not this
internal serial data interface is connected to the 15-way port. If you are connecting to
a computer with RC50-C via serial cable 08-06952-00x, you must set this to
Enabled.
Default value: Disabled