EasyManua.ls Logo

Codan Envoy - Voice Detect Sensitivity; Power down Timeout; Power down Time; Easitalk Mode

Codan Envoy
537 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SETTINGS
SETTINGS > CONFIGURATION > GENERAL
220 ENVOY™ TRANSCEIVER REFERENCE MANUAL
Voice Detect Sensitivity
The Voice Detect Sensitivity entry sets the sensitivity required for voice detection
in the operating environment. In noisy operating environments you may want to
decrease the sensitivity so that mute does not open on general noise.
Range: 1 to 55
Default value: 20
Power Down Timeout
The Power Down Timeout entry sets the length of inactivity after which the
transceiver powers down.
Range: 1 to 10 hour
Default value: Disabled
Power Down Time
The Power Down Time entry sets the local time at which the transceiver powers
down.
NOTE: You must switch the transceiver off then on again for this value to be
activated.
Default value: Disabled
Easitalk Mode
The Easitalk Mode entry selects a noise-reduction algorithm.
Available values: None, Cepstral, Spectral, MMSE
Default value: Cepstral
RF Pre-amp
The RF Pre-amp entry switches the RF pre-amplifier on or off.
If you want to:
increase the receive sensitivity of the RFU, select Enabled
reduce the receive sensitivity of the RFU, select Disabled
Default value: Enabled