SETTINGS
SETTINGS > CALLING > GENERAL
232 ENVOY™ TRANSCEIVER REFERENCE MANUAL
Message Call Alarm
The Message Call Alarm entry sets the delay between receiving a Message call and
sounding the external alarm.
The external alarm is a relay that can be wired by a user to ring a bell or to sound a car
horn. If the external alarm is sounded for messages, it continues for two minutes.
By default, the external alarm is not activated for any Message calls or calls containing
messages.
Available values: Never, Immediate, 10 sec, 30 sec
Default value: Never
Related links:
15-way GPIO connector on page 368
Alert Tones on page 233
Selective Call Alarm
The Selective Call Alarm entry sets the delay between receiving a voice call and
sounding the external alarm.
The external alarm is a relay that can be wired by a user to ring a bell or to sound a car
horn. By default, the alarm delays for 10 sec before sounding. This may be useful
when the transceiver is not closely monitored, but an operator is able to respond to a
local alert tone within 10 seconds. If the call is not answered after this time, the
external alarm is sounded.
The external alarm is sounded continuously for two minutes.
Available values: Never, Immediate, 10 sec, 30 sec
Default value: 10 sec
Related links:
15-way GPIO connector on page 368
External Alarm
The External Alarm entry sets whether the alarm output on the 15-way port is
enabled or disabled.
The external alarm is a relay that can be wired by a user to ring a bell or to sound a car
horn.
Default value: Enabled
Related links:
15-way GPIO connector on page 368