E-GENIUS
96
AV7000 LINEAR CAMERA
Camera Statistics
Belt Speed
Displays the speed of the conveyor belt in millimeters per second or the internal clock for
image acquisition.
Encoder Frequency
Displays the encoder frequency.
Statistics Elapsed Time
Displays the amount of time elapsed from the last reset or the last modification to the configuration
of the system for which
the unit has been collecting statistics. This is reset at startup and when the
“Reset Counts” button is clicked.
Total Packages
The total number of packages detected by the presence sensor, including errors.
Valid Reads
Number of labels completely read by the system (the same label may include more than one
barcode).
No Reads
The total number of unsuccessful code reads for the camera.
Multiple Reads
The total number of times the same bar code symbology has been read by the camera.