E-GENIUS
122
AV7000 LINEAR CAMERA
Encoder Resolution
Displays the encoder/tachometer resolution in pulses per inch (PPI) based on the Encoder Step
calculation. This field cannot be edited.
Maximum Conveyor Speed (m/sec)
When Physical Encoder is Disabled, enter the conveyor speed in meters per second in the field
provided (see formula below).
When Physical Encoder is Enabled, enter the maximum belt speed using the formula below.
Setting the belt speed too high will affect image quality; setting it too low will give you an
exceeded maximum line rate error when the belt exceeds this setting.
Formula: Max conveyor speed x 1.05