SETTING UP THE RANGEFINDER
PRODUCT REFERENCE GUIDE
381
4. In e-Genius under Modify Settings, navigate to Global Settings / Operating
Mode. The Operating Mode window opens.
5. Under RangeFinder Settings, adjust the signal gain value in the Offset to Range-
Finder Gain Setting t
ext field until the right and left pattern generator signals are
symmetrical in the RangerOScope application and gain pattern matches the sam-
ple in the image above.