285.03 Sensor (ADF inverter) late jam
3
Check the sensor (ADF inverter)
for proper connection.
Is the above component
properly connected?
Replace the sensor (ADF
inverter). Go to “Sensor (ADF
inverter) removal” on
page 4-244.
Replace the connections.
4
Place an undamaged document
in the ADF, and perform an ADF
test.
Does the error remain?
Replace the ADF controller
PCBA. Go to “ADF controller
PCBA removal” on page 4-203.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media or media fragments?
Go to step 2. Remove any media or media
fragments.
2
Check the ADF rollers for wear.
Is the ADF feed/pick roller
assembly or the ADF
separation roller guide free of
excess wear?
Go to step 3. Replace the ADF feed/pick roller
assembly. Go to “ADF feed/pick
roller assembly removal” on
page 4-210.
3
Check the sensor (ADF inverter)
for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
inverter).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 5. Go to step 4.
4
Check the sensor (ADF inverter)
for proper connection.
Is the above component
properly connected?
Replace the sensor (ADF
inverter). Go to “Sensor (ADF
inverter) removal” on
page 4-244.
Replace the connections.
Step Action and questions Yes No