3-28 Service Manual
7558-xxx
Scanner Manual Registration
This setting is for making adjustments to control the scanner’s alignment.
To manually register the scanner and the ADF:
1. Scan a sample document to produce a digital image.
Note: For the scanner registration, the sample document must be placed facedown on the scanner glass
in the corner with the arrow.
Note: For the ADF registration, the sample document must be placed faceup on the input bin.
2. Touch SCANNER TESTS from the Diagnostics Menu.
3. Touch Scanner Manual Registration.
4. Check the alignment of the top and left edges of the digital image produced in step 1. Adjust the scanner
and ADF registration by changing the settings below:
Note: Lead refers to the edge of the paper parallel to the scanner carriage. Adjusting FLATBED SS REGI
ADJUST, ADF SIDE1 LEAD REGI ADJUST and ADF SIDE2 LEAD REGI ADJUST changes the left margin
settings. Adjusting FLATBED FS REGI ADJUST, ADF SIDE1 LEAD OFFSET ADJUST and ADF SIDE2
LEAD OFFSET ADJUST changes the top margin settings.
• FLATBED SS REGI ADJUST
• FLATBED FS REGI ADJUST
• ADF SIDE1 LEAD REGI ADJUST
• ADF SIDE1 LEAD OFFSET ADJUST
• ADF SIDE2 LEAD REGI ADJUST
• ADF SIDE2 LEAD OFFSET ADJUST
5. Touch or to adjust the settings.
6. Touch Submit to save the changes or touch Back to return to Scanner Manual Registration without
saving any changes.