Diagnostic aids 3-93
7558-xxx
Front tamping
Front tamping is used in the following cases.
• In the non-staple mode
• When executing front stapling (corner)
The tamper positions during front tamping are shown below.
Rear tamping
Rear tamping is used in the following cases.
• When executing rear stapling (corner)
• When executing dual stapling
Position Description
1 Front tamper home position—sensor (front tamper HP)
2 Front tamper size position
3 Front tamper offset position
4 Rear tamper home position—sensor (rear tamper HP)
5 Rear tamper standby position
6 Rear tamper tamping position
7 Rear tamper offset position
Sensor (front tamper HP)
Front
Sensor (rear tamper HP)
Rear
Rear tamper motor
Rear tamper
Front tamper
Front tamper motor