Diagnostic information 2-227
7558-xxx
486.03 Sensor (lower media exit) late jam
2
Check the sensor (lower media
exit) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
3. Touch Sensor (lower media
exit).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to Step 4. Go to Step 3.
3
Check the sensor (lower media
exit) for proper connection.
Is the above component
properly connected?
Replace the sensor (lower media
exit).
Go to “Sensor (lower media
exit) removal” on page 4-393.
Replace connections.
4
Check the finisher controller
PCBA for proper connection.
Is the above component
properly connected?
Go to Step 5. Replace the connections.
5
POR the machine.
Does the error continue?
Replace the finisher controller
PCBA.
Go to “Finisher PCBA removal”
on page 4-353.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
2
Check the sensor (lower media
exit) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
3. Touch Sensor (lower media
exit).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to Step 4. Go to Step 3.
Step Action and questions Yes No