Diagnostic information 2-165
7558-xxx
295.01, 295.09 and 295.10 Size mismatch jam (no mix-size)
7
Perform a POR.
Does the error remain when the
power is turned off/on?
Replace the ADF controller
PCBA.
Go to “ADF controller PCBA
removal” on page 4-203.
Go to step 5.
Problem resolved
8
Place an undamaged document
in the ADF, and perform an ADF
test.
Does the error remain?
Replace the RIP PCBA.
Go to “RIP PCBA removal” on
page 4-150.
Problem resolved
Step Action and questions Yes No
1 Check the document tray media
guide position.
Are the document tray media
guides set correctly?
Go to step 2. Adjust the document tray media
guides to the proper position.
2
Check the sensor (ADF
document tray width 1) for proper
operation.
th 3) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
document tray width 1).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 4. Go to step 3.
3
Check the sensor (ADF
document tray width 1).
Is the above component
properly connected?
Replace the sensor (ADF
document tray width 1).
Replace the connection.
Step Action and questions Yes No