Reinstallation notes:
Make sure the flat spot on the media entrance roll assembly (H) is installed to the rear.
When replacing the media entrance roll assembly (H), do not touch the rubber surface.
The tension of the belt (entrance/paddle) (E) is automatically adjusted to the force of the spring attached to
the belt tensioner bracket (D).
Tighten the two screws in the order shown.
Finisher PCBA removal
1. Remove the rear upper cover. See “Rear upper cover removal” on page 4-380.
2. Remove the rear lower cover. See “Upper media bin front cover removal” on page 4-423.
3. Loosen the four screws securing the plate (A) to the finisher.
4. Move the plate (A) to the right and outward.
5. Remove the plate (A).
A
Rear