Diagnostic information 2-173
7558-xxx
381.05 Sensor (stapler carriage HP) late jam
Step Action and questions Yes No
1 Check the stapler by moving it
manually.
Does the above component
slide back and forth properly?
Go to step 2. Remove obstructions.
2
Check the sensor (stapler
carriage HP) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (stapler
carriage HP).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 4. Go to step 3.
3
Check the sensor (stapler
carriage shift HP) for proper
connection.
Is the above component
properly connected?
Replace the sensor (stapler
carriage HP). Go to “Sensor
(stapler carriage HP) removal”
on page 4-404.
Replace the connection.
4
Check the stapler carriage motor
assembly for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Stapler carriage
motor (forward).
5. Touch Stapler carriage
motor (rearward).
Does the above component
operate properly?
Go to step 6. Go to step 5.
5
Check the stapler transport motor
for proper connection.
Is the above component
properly connected?
Replace the stapler transport
motor.
Replace the connection
6
Perform a POR.
Does the error continue when
the power is turned off/on?
Replace the finisher controller
PCBA. Go to “Finisher PCBA
removal” on page 4-353.
Problem resolved