EasyManua.ls Logo

Lexmark X95 series - Booklet Staple Fail

Lexmark X95 series
1164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic information 2-207
7558-xxx
Go Back
Previous
Next
381.39 Booklet Staple Fail
7
Check the booklet knife solenoid.
Is the above component
properly connected?
Replace the booklet knife
solenoid. Go to Booklet fold
solenoid removal” on
page 4-325.
Replace the connection.
8
Check the booklet folding/exit
drive motor assembly for proper
operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Booklet folding/exit
motor (forward).
5. Touch Booklet folding/exit
motor (forward).
Does the above component
operate properly?
Go to step 10. Go to step 9.
9
Is the booklet folding/exit drive
motor assembly properly
connected?
Replace the booklet folding/exit
drive motor assembly. Go to
“Booklet folding/exit drive
motor assembly removal” on
page 4-326.
Replace the connection.
10
Perform a POR.
Does the error continue when
the power is turned off/on?
Replace the booklet controller
card assembly. Go to “Booklet
controller card assembly
removal” on page 4-322.
Problem resolved
11
Perform a POR.
Does the error continue when
the power is turned off/on?
Replace the finisher controller
PCBA. Go to “Finisher PCBA
removal” on page 4-353.
Problem resolved
Step Action and questions Yes No
1 Check the booklet unit stapler
assembly.
Is the above component
properly inserted into the
booklet maker unit assembly?
Go to step 2. Ensure that the booklet unit
stapler assembly is properly
inserted.
2
Check the booklet unit interface
connector assembly.
Is the above component free of
damage?
Go to step 3. Replace the booklet unit interface
contact.
Step Action and questions Yes No

Table of Contents

Related product manuals