402.03 Sensor (bridge media exit) late jam
6
Perform a print test.
Does the error remain?
Replace the finisher controller
card assembly.
Go to “Finisher PCBA removal
on page 4-353.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
2
Check the sensor (bridge media
exit) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (bridge media
entrance).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Go to step 4. Go to step 3.
3
Check the sensor (bridge media
exit) for proper connection.
Is the above component
properly connected?
Replace the sensor(bridge media
exit).
Go to “Sensor (bridge media
exit) removal” on page 4-314.
Replace the connection.
4
Check the bridge drive motor for
proper operation.
Caution: When
performing motor
tests, ensure that all
cover and door
interlock switches
are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Finisher Motor Tests.
4. Touch Bridge unit motor.
Does the above component
operate properly?
Go to step 6. Go to step 5.
5
Check the bridge drive motor for
proper connection.
Is the above component
properly connected?
Replace the bridge drive motor.
Go to “Bridge drive motor
removal” on page 4-303.
Go to step 6.
Replace the connections.
Step Action and questions Yes No