3. Disconnect the connector from the HCF feed lift motor assembly (A).
4. Remove the four screws securing the HCF feed lift motor (A) to the HCF media feed unit assembly (B).
5. Remove the HCF media feed lift motor (A).
HCF feed roll assembly removal
1. Open the HCF top door.
2. Open the HCF feed unit assembly.
3. Push the two ends of the HCF feed roll assembly (A) inward, and move it upward in the direction of the
arrow to release it from the HCF media feed unit assembly (B).
4. Remove the HCF feed roll assembly (A).
Note: When removing the HCF feed roll assembly (A), do not touch the rubber surface.
Note: Before re-installing the HCF feed roll assembly (A), do not touch the rubber surface.
A
B
Connector
A
B
Front