3-26 Service Manual
7558-xxx
PRINTER SETUP
Configuration ID
This setting enables a user to change both Configuration ID 1 and Configuration ID 2.
Mono and Color Page Count
The values of these settings enable a user to gauge the amount and type of usage on a device. The Mono Page
Count setting’s value will equal the value of the Picked Sides meter. The Color Page Count setting’s value will
equal the value of the Total Color sub-meter within the Imaged Printed Sides meter.
Parallel Strobe Adjustment (all parallel ports)
This setting enables the user to adjust the amount of time the strobe is sampled in order to determine if valid
data is available on the parallel port. Each time this value is incremented by 1, the strobe is sampled 50
nanoseconds longer. Each time this value is decreased by 1, the strobe is sampled 50 nanoseconds less. When
the value of this setting is 0, the factory default value is used to determine the length of time the strobe is
sampled.
To change this setting:
1. From the Diagnostics Menu, navigate to PRINTER SETUP.
2. Select Par 1 Strobe Adj.
3. Touch or to change the value.
4. Touch Submit to save the setting, or touch Back to return to the Diagnostics Menu without saving any
changes.
Permanent Page Count
The value of this setting indicates the total number of pages that have been printed by the device.
Reset Color Calibration
This setting enables the device to adjust the alignment of its color planes using pre-programmed default values.
Using this setting to adjust color plane linearization may not provide a calibration as effective as using Automatic
Color Adjust Calibration. While this text executes, the panel posts Resetting.
Serial Number
This setting records the device’s 13-character (last character is a null value) serial number that was assigned by
manufacturing.
U.S. / Non-U.S. Defaults
The value of this setting determines whether the device uses the U.S. or Non-U.S. factory default value.
To change this setting:
1. From the Diagnostics Menu, navigate to PRINTER SETUP.
2. Select Defaults.
3. Touch or to change the value.
4. Touch Submit to save the setting, or touch Back to return to the Diagnostics Menu without saving any
changes.