282.01 Sensor (ADF pre registration) static jam
282.03 Sensor (ADF pre registration) late jam
7 Place an undamaged document
in the ADF, and perform an ADF
test.
Does the error remain?
Replace the ADF controller
PCBA. Go to “ADF controller
PCBA removal” on page 4-203.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
2
Check the sensor (ADF feed out)
for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
pre registration).
Does the display on the
operator panel change every
time the sensor actuator is
operated?
Go to step 4. Replace the sensor (ADF
pre registration). Go to “Sensor
(ADF pre-registration)
removal” on page 4-244.
3
Check the sensor (ADF
pre registration) for proper
connection.
Is the above component
properly connected?
Go to step 4. Replace connections.
4
Place an undamaged document
in the ADF, and perform an ADF
test.
Does the error remain?
Replace the ADF controller
PCBA. Go to “ADF controller
PCBA removal” on page 4-203.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
Step Action and questions Yes No