EasyManua.ls Logo

Lexmark X95 series - IGBT Temperature Sensor Failure; Input Low Current Error

Lexmark X95 series
1164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic information 2-63
7558-xxx
Go Back
Previous
Next
126.09 IGBT temperature sensor failure
126.12 Input low current error
2
Replace the fuser driver PCBA.
Go to “Fuser driver PCBA
removal” on page 4-90.
Does the error remain?
Go to step 3. Problem resolved
3
POR the machine.
Does the error continue?
Replace the upper printer engine
PCBA.
Go to “Upper printer engine
PCBA removal” on page 4-187.
Problem resolved
Step Action and questions Yes No
1 Check the fuser driver PCBA.
Is the above component
properly connected?
Go to step 2. Replace the connections.
2
Replace the fuser driver PCBA.
Go to “Fuser driver PCBA
removal” on page 4-90.
Does the error remain?
Go to step 3. Problem resolved
3
POR the machine.
Does the error continue?
Replace the upper printer engine
PCBA.
Go to “Upper printer engine
PCBA removal” on page 4-187.
Problem resolved
Step Action and questions Yes No
1 Remove the sub LVPS PCBA. Go
to “Sub LVPS PCBA removal
on page 4-165.
Check the fuser driver PCBA.
Is the above component
properly connected?
Go to step 2. Replace the connections.
2
Replace the fuser driver PCBA.
Go to “Fuser driver PCBA
removal” on page 4-90.
Does the error remain?
Go to step 3. Problem resolved
3
Replace the fuser assembly. Go
to “Fuser assembly removal”
on page 4-84.
Does the error remain?
Go to step 4. Problem resolved
Step Action and questions Yes No