2-226 Service Manual
7558-xxx
486.01 Sensor (lower media exit) static jam
3
Check the sensor (upper media
exit) for proper connection.
Is the above component
properly connected?
Replace the sensor (upper media
exit).
Go to “Sensor (upper media
exit) removal” on page 4-406.
Replace connections.
4
Check the buffer/transport motor
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Buffer/transport
motor.
Does the above component
operate properly?
Go to step 6. Go to step 5.
5
Check the buffer/transport motor
for proper connection.
Is the above component
properly connected?
Replace the buffer/transport
motor.
Go to “Stepper motor (buffer/
transport) and belt (buffer/
transport) removal” on
page 4-414.
Replace the connection.
6
Check the finisher controller
PCBA for proper connection.
Is the above component
properly connected?
Go to Step 5. Replace the connections.
7
POR the machine.
Does the error continue?
Replace the finisher controller
PCBA.
Go to “Finisher PCBA removal”
on page 4-353.
Problem resolved
Step Action and questions Yes No
1 Check the media path.
Is the media path free of any
media fragments?
Go to step 2. Remove any media or media
fragments.
Step Action and questions Yes No