381.30 Sensor (booklet front tamper HP) late jam
5
Check the bridge drive motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Bridge unit motor.
Does the above component
operate properly?
Go to step 7. Go to step 6.
6
Is the bridge drive motor
properly connected?
Replace the bridge drive motor.
Go to “Bridge drive motor
removal” on page 4-303.
Replace the connection.
7
Perform a POR.
Does the error continue when
the power is turned off/on?
Replace the finisher controller
PCBA. Go to “Finisher PCBA
removal” on page 4-353.
Problem resolved
Step Action and questions Yes No
1 Check the booklet unit interface
connector assembly.
Is the above component free of
damage?
Go to step 2. Replace the booklet unit interface
contact.
2
Check the main connector on the
booklet unit sensor interface
cable assembly.
Is the above component free of
damage?
Go to step 3. Replace the booklet sensor
interface cable assembly.
3
Check the main connector on the
booklet unit motor interface cable
assembly.
Is the above component free of
damage?
Go to step 4. Replace the booklet motor
interface cable assembly.
4
Check the booklet front tamper by
moving it manually.
Does the above component
slide back and forth properly?
Go to step 5. Remove obstructions.
Step Action and questions Yes No