2-228 Service Manual
7558-xxx
3
Check the sensor (lower media
exit) for proper connection.
Is the above component
properly connected?
Replace the sensor (lower media
exit).
Go to “Sensor (lower media
exit) removal” on page 4-393.
Replace connections.
4
Check the entrance/paddle motor
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Entrance/paddle
motor.
Does the above component
operate properly?
Go to step 6. Go to step 5.
5
Check the entrance/paddle motor
for proper connection.
Is the above component
properly connected?
Replace the entrance/paddle
motor.
Go to “Stepper motor
(entrance/paddle) and belt
(entrance/paddle) removal” on
page 4-416.
Replace the connection.
6
Check the exit stepper motor for
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Exit motor.
Does the above component
operate properly?
Go to step 8. Go to step 7.
7
Check the stepper motor for
proper connection.
Is the above component
properly connected?
Replace the stepper motor.
Go to “Stepper motor (exit)
assembly and belt (exit)
removal” on page 4-417.
Replace the connection.
8
Check the finisher controller
PCBA for proper connection.
Is the above component
properly connected?
Go to Step 9. Replace the connections.
Step Action and questions Yes No