215916 315 Revision A
4.9 Operating with R113 or R216 Rotary Disc Header
4.9.1 Disc Speed
The disc speed should be set according to the crop type and the cutting conditions.
Refer to the header operator’s manual for information on setting the disc speed.
Setting Disc Speed
The default disc speed is 2000 rpm. The minimum disc speed is 1500 rpm. The maximum disc speed is 2700 rpm. Follow
these steps to adjust the disc speed.
DANGER
Ensure that all bystanders have cleared the area.
Figure 4.461: GSL
1. Engage the header. For instructions, refer to Engaging and
Disengaging the Header, page 257.
2. Adjust the disc speed with DISC SPEED INCREASE (A) or
DISC SPEED DECREASE (B) buttons on the ground speed
lever (GSL).
NOTE:
The disc speed increases by 50 rpm per momentary button
push, or at a rate of 100 rpm/sec if the button is pushed
and held.
Adjusting Disc Pressure Alarm
Adjusting the disc alarm allows the operator to set an alert to inform them that the disc is operating at a desired pressure.
A lower setting will cause the alarm to be set off more often; a higher setting will allow the alarm to be set off less
frequently. This adjustment requires the header to be in operation.
DANGER
Ensure that all bystanders have cleared the area.
Figure 4.462: Disc Header Run Screen 1
1. If RUN SCREEN 1 is not already displayed, press soft
key 1 (A) on the Harvest Performance Tracker (HPT) to
display draper RUN SCREEN 1.
OPERATION