ND-70348 (E) CHAPTER 4
Page 112
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
–
511
DATA
(DATA)
00
–
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
70
b
0
Called Number Display when forwarding to Attendant Console
0/1 = Out/In Service
b
1
Flashing display of Line Lockout on Attendant Console BLF
0/1 = In Service/Out
b
2
Route No. Display on Attendant Console
b
3
0
b
4
One digit dialing instead of SHF (DP TEL only)
0/1 = Not Required/Required
b
5
Priority order for answering via ANSWER key
0 = Priority according to Type of Call
1 = Priority according to the order call termination
b
6
Announcement Trunks used for Delay Announcement – UCD
service
0/1 = Common/per UCD group
b
7
Send Warning Tone to interrupted parties when Executive
Right of Way service is in operation
0/1 = Required/Not Required
71 00
b
0
Call Back Automatic Cancel Timer
Value = TX (X1H to XFH) × MTC (3.5 minutes)
This Timer can be assigned a value from 3.5 minutes to 52.5
minutes.
b
1
b
2
b
3
b
4
Not used
b
5
b
6
b
7
Enable Call Back Automatic Cancel Timer
0/1 = No/Yes
TN RT TRK
b
3
0
b
2
0:
RT TRK
b
3
0
b
2
1: