ND-70348 (E) CHAPTER 4
Page 111
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
511
DATA
(DATA)
00
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
169
b
0
Return transferred call to transferring party after Recall Timer
expires (Call Transfer – All Calls or Blind Transfer to Station
service)
0/1 = Recall/No Recall, or execution of Call Forwarding –
Don’t Answer (when C.F. – Don’t Answer is set at the transfer
destination station)
b
1
Send short tone when a call forwarded via C.F. – All Calls ser-
vice is answered.
0/1 = Not Required/Required
b
2
Send short tone when a recalled C.F. – All Calls call is an-
swered.
0/1 = Not Required/Required
0
b
3
Not used
b
4
b
5
Hunting Group when transferred party is busy (Station Hunting
after C.F. – Busy Line):
0 = Hunt in Transferring Party’s Group
1 = Hunt in Transferred Party’s Group
b
6
Send Warning Tone to indicate Intercom Bridge (Auto/Manual
and Dial Intercom service)
0/1 = Not Required/Required
b
7
Multiple Call Forwarding – Busy Line/All Calls
0/1 = Out/In Service