ND-70348 (E) CHAPTER 4
Page 110
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
–
511
DATA
(DATA)
00
–
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
67 00
0
b
0
Not used
0
b
1
0
b
2
0
b
3
0
b
4
0
b
5
0
b
6
SMDR Control Circuit Card Designation
0/1 = MRC/SMDC (Always assign “0”)
0
b
7
SMDR Sending Designation
0/1 = AP/SMDC (Always assign “0”)
68
b
0
Operating method for busy station service (Call back, Execu-
tive Right of Way, etc.)
0/1 = SHF + Access Code/Last Digit + Access Code
b
1
Operating method for Individual Trunk Access (ATT) service
0 = Route No. + Trunk No.
1 = C.O. Code (as assigned via command “ACOC”)
b
2
Ringing Signal type for TAS indicator
0/1 = Interval/Continuous
b
3
OG Trunk Queuing (On-Hook) Automatic Cancel
0/1 = Out/In Service
b
4
TKSL key on the Attendant Console (for Individual Trunk Ac-
cess service)
0/1 = Out/In service
0
b
5
Not used
b
6
Ground Button (GB) used for SHF
0/1 = Not Required/Required
Used only
for Special
Common
Battery
Telephones
b
7
OG call operation
via Attendant
Console
Direct Dial
Access
0 Off-Hook
Off-Hook with
depressing GB
1
Off-Hook with
depressing GB
Off-Hook
–
b
7