ND-70348 (E) CHAPTER 4
Page 109
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
–
511
DATA
(DATA)
00
–
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
64
b
0
µ law/A law for TSW
0 = µ law (Japan, North America, Canada, and Hong Kong)
1 = A law (Europe, other nations)
b
1
Display of Call Waiting Lamp (on Attendant Console) service
0 0 = When PA lamp illuminates
0 1 = When busy lamp field is not displayed
1 0 = Always
11 = –
b
2
b
3
Howler Tone sending service
0 0 = Out of Service
0 1 = Send one time only
1 0 = Repeat every 30 sec.
11 = –
Note:
The Sending Timer may be changed to a value other
than 30 sec. via SYS-1, INDEX = 146.
b
4
0
b
5
Not used
0
b
6
Type of Attendant Camp-On
0/1 = Automatic/Semi-Auto (Normally Assign “0”)
b
7
Music On Hold service
0/1 = Out/In Service
65
Maximum Number of Routes
IMX 1~255 = 01~FF Hex
66 00 Not used
b
2
b
1
b
4
b
3