ND-70348 (E) CHAPTER 4
Page 108
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
62
0
b
0
Not used
0
b
1
0
b
2
0
b
3
0
b
4
0
b
5
b
6
ACT/ST – BY Change over at Routine Diagnosis
0 0 = Every time
0 1 = Once a week (On Sunday)
1 0 = Once a month (On the 1st Sunday of the month)
11=–
Note: Assign the Routine Diagnosis Program start time in
SYS-1, INDEXes 87 and 88.
b
7
63 00
b
0
Blind Transfer for stations in service
0/1 = No/Yes
b
1
Not used
b
2
b
3
b
4
Not used
b
5
Exclusive Hold for stations
0/1 = Yes/No
b
6
Not used
b
7
b
7
b
6