ND-70348 (E) CHAPTER 4
Page 107
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
60
0
b
0
Not used
0
b
1
0
b
2
b
3
UCD Queuing
0/1 = Required (RBT)/Not Required (BT)
(Most = 0 when the MCI is in services.)
b
4
Nailed Down Connection (Fixed Connection) service
0/1 = Out/In service
b
5
Send Warning Tone to interrupted parties when Attendant In-
terruption service is operated.
0/1 = Required/Not Required
0
b
6
Not used
0
b
7
61
0
b
0
Not used
0
b
1
0
b
2
0
b
3
0
b
4
b
5
Call Waiting Display – UCD/ACD Service
0/1 = Out/In Service
0
b
6
Not used
0
b
7