ND-70348 (E) CHAPTER 4
Page 120
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
86
b
0
System Message “7-O” is registered when no errors are detect-
ed by the Routine Diagnosis Program (Refer to INDEX 89 and
90)
0/1 = Not Registered/Registered
b
1
System Message “7-P” is registered when an error is detected
by the Routine Diagnosis Program (Refer to INDEX 89 and
90)
0/1 = Not Register/Register
b
2
Fault Recovery Pattern upon TRK Ineffective Hold Detection
0 0 = Release all calls other than basic calls (two-way
calls), and register all call status.
0 1 = Register all call status
1 0 = Release all calls and register all call status
1 1 = Not used
b
3
b
4
System Message Automatic output to System printer
(SYS 1, INDEX = 38, 39)
0/1 = Not Required/Required
0
b
5
Not used
0
b
6
Not used
1
b
7
System Message Contents
0/1 = Simplified/Detailed (Always assign 1.)
87
“Hour” data is assigned using a deci-
mal number (Military Time)
Example: 2:00 a.m. –
This data is entered as
02.
Example: 2:30 p.m. –
This data is entered as
14.
Routine Diagnosis
Program Start Time
Note: When both
Index 87
and Index
88 are as-
signed
data “FF”
Hex, the
Routine
Diagnosis
Program is
not execut-
ed.
88
“Minute” data is assigned using a dec-
imal number (Military Time)
Example: 2:00 a.m. –
This data is entered as
00.
Example: 2:30 p.m. –
This data is entered as
30.
b
3
b
2