ND-70348 (E) CHAPTER 4
Page 121
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
89
b
0
Main Memory Check (MM Program Memory)
0/1 = No/Yes
b
1
DM Check (DM = Data Memory)
0/1 = No/Yes
b
2
TSW Active/Standby Changeover for Dual Systems
0/1 = No/Yes
b
3
CPU Active/Standby Changeover for Dual Systems
0/1 = No/Yes
(For 16-IMG system)
SP ACT/STBY Changeover
0/1 = No/Yes
b
4
Trunk Ineffective Hold Check
0/1 = No/Yes
b
5
Trunk Ineffective Hold Detect
0/1 = No/Yes
b
6
Call Forward Data Clear
0/1 = No/Yes
b
7
Not used
90
0
b
0
Not used
b
1
Backup Call Forwarding, and Individual Speed Data and Name Display
Data to HDD (See Index 304)
0/1 = No/Yes
0
b
2
Not used
b
3
Residual link detect
0/1 = No/Yes
Note:
Valid since the release 5 software.
b
4
LP ACT/STBY Changeover (for 16-IMG system)
0/1 = No/Yes
b
5
CMP ACT/STBY Changeover (for 16-IMG system)
0/1 = No/Yes
0
b
6
Not used
0
b
7

Table of Contents