ND-70348 (E) CHAPTER 4
Page 152
Revision 3.0
ASYD
Note: Room Cutoff (RSC13)
Do Not Disturb (RSC14)
Room Cutoff and Do Not Disturb (RSC15)
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
169
0
b
0
Miscellaneous Timer
Counter (MTC) is to be
assigned a value from 0
to F Hex, (0~15)
Announcement trunk release timer
to reset the announcement. Avail-
able only with single connection.
2 sec. × ΜTC
(If MTC = 0 Hex: 30 sec.)
(for Hotel
system)
0
b
1
0
b
2
0
b
3
b
4
When the system provides Automatic Wake-Up Service, and
the number of calls for which automatic wake-up at the same
time has been set exceeds the predetermined overflow
threshold value (512 calls/LP), assign data specifying how
many minutes earlier the wake-up time for the overflowed
calls will be 5 min. × N Hex.
b
5
b
6
b
7
170
b
0
Room status data (b
2
, b
1
, b
0
) to be set at the time of Checkout
Do not assign other data.
b
1
b
2
b
3
Restriction at the time of Do Not Disturb and Room Cutoff
0/1 = Room Status Memory/Change of RSC Note
b
4
Timing Start
0/1 = Not Required/Required
b
5
SHF from a Guest Station while talking
0/1 = Effective (goes to ORT)/Ineffective (goes to Attendant
Console)
b
6
Day/Night Change of RSC
0 = Time zone changing per Day/Night Change Table
(ADNR)
1 = By NIGHT key of the Attendant Console
b
7
Message Registration
0/1: Yes/No
b
2
b
1
b
0
b
2
b
1
b
0
0 0 0 = – 0 1 0 = Cleaned
0 0 1 = To be Cleaned 0 1 1 = Ready for
Occupancy