EasyManuals Logo

NEC NEAX 7400 IMX User Manual

NEC NEAX 7400 IMX
857 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
ND-70348 (E) CHAPTER 4
Page 167
Revision 4.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
225 00 Not used
226
b
0
Call Forwarding Service by Calling Number Data
(“AFCP” command)
Separate or
Common Ten-
ant Data Table
development for
the respective
commands
0/1 = Separate/
Common
Note:
When
data “1” is
assigned, data
must be
assigned for
Tenant 1 (TN =
1) in the respec-
tive commands.
b
1
Automatic Number Indication Expansion Data
(“AANDE”)
0
b
2
Not used
0
b
3
0
b
4
0
b
5
0
b
6
0
b
7
227 00 Not used
228 00 Not used
229 00
b
0
Disable Attendant Console Loop keys when that console is in Night Mode
(Night Key engaged)
0/1 = No/Yes
0
b
1
Not used
b
2
With the key pad pressed by the Attendant while talking with the incoming
call, DTMF (PB) signal is sent out to the incoming call.
0/1 = Not Required/Required
b
3
Day/Night Change Message Automatic Output.
0/1 = Out/In Service
0
b
4
Not used
0
b
5
0
b
6
0
b
7
230
0
b
0
-
b
2
Not used
b
3
Timing for MFC Forward Signal Sending
0/1 = Backward Signal Stop/Backward Signal Receiving
0
b
4
-
b
6
Not used
b
7
Receive/Send Timing for ISDN/CCIS message.
0/1 = 32ms/128ms
231 00 Not used

Table of Contents