ND-70348 (E) CHAPTER 4
Page 168
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
232 00
b
0
Call Forward All Clear
0/1 = No/Yes
Used in con-
junction with
Indexes 89 and
90
b
1
Call Forward Busy Clear
0/1 = No/Yes
b
2
Call Forward No Answer Clear
0/1 = No/Yes
b
3
Not used
b
4
b
5
b
6
b
7
233 00 Not used
234
b
0
Connection acknowledge polarity reversal signal
0/1 = Not Required/Required (Multi-Frequency Signaling)
0
b
1
Not used
b
2
b
3
b
4
b
5
b
6
b
7
235
Not used
236 00
Not used
237
0
b
0
-b
6
Not used
b
7
When a call terminated to vacant number by Direct
Inward Dialing
0/1 = Send Busy Tone/Reorder Tone
238 00
Not used
239 00
0 b
0
-b
3
Not used
b
4
Assign “1” for Remote Access to system
0 b
5
-b
7
Not used