ND-70348 (E) CHAPTER 4
Page 200
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 31
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
3
11
b
0
PBST: PB signal (DTMF) timer for D
term
.
This data is to be assigned from 0 Hex to F Hex (0~15).
Timer Value setting is (PBST + 1) × 128 msec.
b
1
b
2
b
3
0
b
4
Not used
0
b
5
0
b
6
0
b
7
12
b
0
ON Time is to be assigned a
value from 1 Hex to F Hex
(1~15). (Unit of Time is Sec-
onds.)
Timer Value for Data Com-
munication RS-232C CI
(Call Indicator; same as RI:
Ring Indicator) Signal
Note: When this data is
00 Hex, Default
data is automatical-
ly set to 2 sec.–ON,
4 sec.–OFF
b
1
b
2
b
3
b
4
OFF Time is to be assigned a
value from 1 Hex to F Hex
(1-15). (Unit of Time is Sec-
onds.)
b
5
b
6
b
7
13 00 Not used
31 00 Not used
ON
TIME
OFF
TIME
CI
SIGNAL
~
~
~

Table of Contents