ND-70348 (E) CHAPTER 4
Page 199
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 31
DATA
(DATA)
00-FF
(Hex)
BIT CORRE-
SPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
3
6 00 0 Not used
7
b
0
ON time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
Timer Value for Ringer used for
Ringer Pattern 5.
Note: When this data is 00 Hex,
ROM data (2 sec.-ON, 4 sec.-
OFF) is automatically set.
b
1
b
2
b
3
b
4
OFF time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
b
5
b
6
b
7
8
b
0
ON time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
Timer Value for Ringer used for
Ringer Pattern 6.
Note: When this data is 00 Hex,
ROM data (1 sec.-ON, 2 sec.-
OFF) is automatically set.
b
1
b
2
b
3
b
4
OFF time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
b
5
b
6
b
7
9
b
0
ON time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
Timer Value for Ringer used for
Ringer Pattern 7.
Note: When this data is 00 Hex,
ROM data (1 sec.-ON, 1 sec.-
OFF) is automatically set.
b
1
b
2
b
3
b
4
OFF time is to be assigned a value
from 1 Hex to F Hex (1–15). (Unit of
Time is Second.)
b
5
b
6
b
7
10
b
0
Reception Sensitivity Level of the MFC Register
0: -28 dBm 8: -36 dBm
1: -29 dBm 9: -37 dBm
2: -30 dBm A: -38 dBm
3: -31 dBm B: -39 dBm
4: -32 dBm C: -40 dBm
5: -33 dBm D: -41 dBm
6: -34 dBm E: -42 dBm
7: -35 dBm F: -43 dBm
b
1
b
2
b
3
0
b
4
Not used
0
b
5
0
b
6
b
7
Reception Sensitivity Level of the MFC Register
0/1 = –38 dBm/Assigned in b
0
~b
3

Table of Contents